SC-1000 Scale Control & Metal Chelant by Orenda (Quart)
Also available in: 12 x 1-Quart and 4 x1-Gallon cartons, 5-Gallon, 15-Gallon and 55-Gallon polyethylene drums with standard bung openings, and 275-Gallon IBC containers.
SC-1000 Scale Control & Metal Chelant is a proprietary, patent pending, non-phosphorus containing aqueous formulation for control of carbonate scale and metals staining in recreational water systems.Applied as directed, SC-1000 is compatible with materials of pool and spa construction, and othertreatment chemicals applied in accordance with manufacturer’s recommendations. SC-1000 is especially effective at controlling salt water generator (SWG) electrode scale formation without contributing ortho-phosphates to the water which inhibit chlorine sanitation and act as nutrients for algae growth.
PHYSICAL & CHEMICAL PROPERTIES Specific Gravity @ 60ºF 1.335 Typical Density, lbs./gallon 11.13 Typical Flash Point, ºF Nonflammable Freezing Point, ºF 30 Typical Boiling Point, ºF 212 Typical Physical Form clear liquid Odor Essentially none pH (as received) 10.3 – 11.4 Typical Solubility Complete in water
Orenda Technologies, Inc. warrants that this material is reasonably fit for the purposes stated in our literature when used in accordance with our written and verbal directions. Under no circumstances shall Orenda Technologies, Inc. be liable for incidental, consequential or other damages from alleged negligence, breach of warranty, strict liability or any other theory arising out of the use or handling of this product. Neither this warranty nor any otherwarranty of merchantability or fitness of purpose, either express or implied, extends to the use of this material contrary to our directions, or under conditions not reasonably foreseeable by Orenda Technologies, Inc.. Prior to SC-1000 application, raise the free chlorine level to 6 to 8 ppm, then add SC-1000 at an initial rate of one (1) quart per 10,000 gallons of water by pouring either into the skimmer or around the perimeter ofthe water, with the circulation pump on. To ensure continued protection against scale formation and metalstaining, the following maintenance dose should be applied: calcium hardness less than 300 ppm – six (6) ounces per 10,000 gallons every one to two months; calcium hardness greater than 300 ppm – six (6) ounces per 10,000 gallons every month.
HANDLING & STORAGE SC-1000 is inherently stable with an indefinite shelf life under normal conditions of storage at temperaturesless than 120ºF. Prevent freezing to avoid container damage and loss of product. Though SC-1000 isnontoxic and non-hazardous, gloves and appropriate eye protection should be worn when handling andusing the product. Review the product MSDS before using. KEEP AWAY FROM CHILDREN. APPLICATION AVAILABILITY Copyright © 2006 by Orenda Technologies, Inc.
|